A Complete Rapid Microbial Detection Solution

The following videos demonstrate how the Celsis Advance II instrument is prepared for rapid testing, reducing incubation times to 24-36 hours for bioburden/microbial limits, and 6 days for final product sterility. We offer these demonstrations in-person on a global scale; however, as a prerequisite, we encourage you to watch these informational videos. Our expert will walk you through preparing reagents, controls, and using the onboard Celsis.im software to run assays and review results. 

 

Introduction to Celsis® ATP-Bioluminescence Assays 
Learn how the ease and flexibility of the Celsis Advance II luminometer allows for seamless integration with your current quality control system. Capable of performing 120 tests per hour, you will gain an overview of the functions, features, and benefits of Celsis instruments and Celsis AMPiScreen® ATP assay kits.

 

 

Instrument Startup Procedure
Conduct the simple daily startup procedure used to prepare Celsis instruments and get an introduction of the Celsis.im software interface. Performing this simple wash, rinse, and prime procedure with Celsis reagents prepares the Celsis Advance II to test hundreds of samples with its industry-leading throughput.

 

Daily Controls
Daily controls are used prior to running any test samples on the system to ensure the instrument and reagents are prepared to detect contamination in the remainder of the samples. These controls include interim blanks, reagent blanks, and positive controls, which you will learn how to prepare and set up in the Celsis.im software during this video.

 

Celsis ATP-bioluminescence Assays
Learn how Celsis assays are prepared, loaded, and analyzed on the Celsis Advance II luminometer. Celsis assays align with your existing sample preparation methods, such as for bioburden, microbial limits, and sterility using both membrane filtration and direct inoculation test methods. Celsis instruments can provide pass/fail results in less than one hour, controlling the entire assay through automated, timed reagent injections. 

 

Analyzing Results
This video will introduce you to the simple, data integrity-compliant analysis reporting functions of Celsis luminometers. Utilizing Celsis.im software, included with both the Celsis Advance II and the smaller Celsis Accel®, you will see a preview of how results are interpreted and reported as Relative Light Units (RLUs) in this video.

 

 


Celsis Advance II™

Still unsure if the Celsis® platform is the right fit for your needs?
Use our Financial Impact Assessment tool to build your case by outlining the rationale behind your selection and the associated risks, costs, and ROI.

Discover the benefits