MALDI-TOF Instrumentation Powered by Accugenix® Microbial Databases
While traditional microbiological identification approaches require time-consuming incubation steps and ancillary tests, Axcess rapidly identifies up to 96 unknown microorganisms in just 15 minutes. Confirm your product quality and quickly respond to potential contamination events within your facility.
Axcess® key features: speed and convenience at your fingertips
- Easy-to-use benchtop system, requiring no more than a simple colony to obtain a species-level ID
- Identify up to 96 samples in just 15 minutes, compared to 18+ hours required by most phenotypic methods and PCR systems
- Largest industry-sourced global MALDI-TOF microbial database with over 17,400 organism entries representing more than 6,000 species
- Enhance your contamination control strategy (CCS) with compliant Environmental Monitoring (EM) data management tools in the Customer Web Portal
- For samples that do not yield an ID, get AccuGENX-ID® DNA sequencing services at no additional charge
- Fully encrypted sample data and secure LIMS integration
- Rely on Bruker or Axcess support and gain access to decades of technical research-backed expertise and IT troubleshooting

Axcess® Overview
Learn more about system advantages, site preparation guide, instrument specifications, and description of service agreements.
Get the details
A Partnership with Bruker to Check All Your Boxes
In 2013, we announced a partnership with Bruker to provide rapid, accurate microbial identifications to the industrial microbiology market, including pharmaceutical, biopharmaceutical, home and personal care, and other manufacturing industries.
Through this agreement, we are able to offer the Axcess system, which combines the benefits of the Bruker MALDI Biotyper with a custom data analysis software solution, allowing for instantaneous access to the Accugenix microbial database for identifications.
For over a decade, this partnership allowed us to develop extensive knowledge and expertise in the field, maximize performance for environmental monitoring applications, and simplify customers’ validation commitments.
“We are delighted to be working with Charles River on the distribution of the MALDI Biotyper into the industrial and pharmaceutical microbiology markets. From my experience, the technical and sales teams that Charles River brings to this effort are among the best and most respected in these industries, (…) With Charles River products in virtually every pharmaceutical microbiology laboratory, we are looking forward to working with Charles River to expand our efforts to make the MALDI Biotyper the new standard in microbial identification for industrial microbiology”
Dr Gary Kruppa, Vice President of Business Development at Bruker
“By partnering with Bruker Daltonics, the recognised industry leader in MALDI-TOF mass spectrometry, we have reinforced our mutual commitment to meeting our customers’ microbial identification needs with innovative and comprehensive environmental monitoring solutions. Our entire team here at Charles River is excited to introduce the Axcess System to the market and to represent the MALDI Biotyper by providing the same professionalism, responsiveness and expertise Bruker is known for.’’
Foster Jordan, Corporate Senior Vice President, Charles River
See Axcess® in Action
AGC Biologics, a leading CDMO, shares how they brought ID technology in-house to address the criticality of speed and responsiveness to contamination during a production run.
Explore Their Results
Explore Solution Details
| Product Line | Product | Code |
| Axcess® MALDI-TOF System | Axcess® Sirius One MALDI Biotyper package
| AXC750 |
Axcess® Sirius MALDI Biotyper package The sirius package includes all the features and accessories as the Axcess® sirius one MALDI Biotyper package, with the added benefit of both positive and negative ion mode for microbial identifications and future applications. | AXC850 | |
| Axcess® MALDI Biotyper-CM Reagents & Consumables | Bacterial test standard (BTS) | AXC115 |
| Matrix HCCA | AXC155 | |
| Conidia IDFP fungi agar plates, 20-pack | AXC320 | |
| MSP adapter for MALDI Biotarget | AXC4800AD | |
| MALDI Biotarget 96 disposable target plate 20/pk | AXC9600D | |
| Axcess® Plans | Axcess® Startup Package The Axcess® Startup package is available with:
*The Startup package begins when the Axcess® Complete Validation is completed and runs for 1 year. A renewal contract is issued at the end of the Startup Package. | AXC8000 |
| OR | ||
Axcess® Premium Plan
| AXCESS-10 |
*Contact your Account Specialist to review coverage for each service package.

Your Guide to Fast, Accurate Microbial Identification
With so many ID methods and providers out there, it’s tough to choose. We’ll guide you through how each test delivers results, so you can find the best fit for you.
Check it out
FAQs About MALDI-TOF Mass Spectrometry
-
What does the acronym MALDI-TOF stand for?
MALDI-TOF stands for Matrix-Assisted Laser Desorption/Ionization Time-of-Flight.
-
Is mass spectrometry a recognized technology for microbiology testing?
Current trends indicate acceptance of MALDI-TOF technology for microbiology testing in the pharmaceutical, medical device, and consumer care markets when paired with industry-relevant microbial databases. Using MALDI-TOF for microbiology testing lowers the cost of routine identifications in your Environmental Monitoring (EM) program.
-
Why are microbial organism libraries important for accurate identification with mass spectrometry?
While MALDI-TOF significantly improves accuracy compared to phenotypic methods, any identification technology is only as good as the database that it references. The MALDI-TOF instrument software can’t identify something it has never seen before, therefore, access to relevant, validated microorganism reference libraries is critical for optimizing the identification rate. A better identification rate helps maximize the return on your capital investment due to reduced occurrences of low confidence IDs or no IDs that can result in significant, unexpected outsourcing costs and potentially delay product release.
-
Can MALDI-TOF identify mold?
MALDI-TOF can identify molds using an ethanol extraction method, increasing the repeatability and reliability of acquiring spectra for identifications. Our library, combined with our innovative sample processing approach using a specialized media, Conidia IDFP Agar Plates, generates significantly higher identification rates compared to the industry average.
-
If I transition from outsourcing with Accugenix to an in-house Axcess System, do we still have access to the outsourcing data?
Yes, all Accugenix outsourcing data and any Axcess data you generate is securely maintained in the GMP-validated Customer Web Portal, available for use with the included tracking and trending reporting tools.
-
How accurate is MALDI-TOF?
This technology can outperform off-the-shelf ID systems while approaching the accuracy of DNA sequencing with AccuGENX-ID, making it ideal and cost-effective for routine ID work.

Bring Rare Bugs Around the World to Your Screen
Turn your device into a gallery of microbial science with 12 wallpapers featuring rare organisms identified across our global laboratory network.
Download Wallpapers