Benefits of the PRS 3 Microplate Reader
Enhanced Testing Capabilities
By leveraging our unparalleled LAL and rCR reagents, this instrument provides accurate and reliable quantitative endotoxin test results while meeting today's stringent testing requirements. Users can effortlessly switch between every Endosafe reagent, facilitating faster and more reliable testing.
Promoting Sustainability with Endosafe Trillium rCR
Integrating environmentally conscious alternatives into your testing workflow is now simpler than ever with recombinant reagents like Endosafe Trillium. Clients can ensure product safety while prioritizing sustainability. The PRS 3 system allows users to seamlessly transition between LAL and rCR vial-based reagents, offering flexibility to test multiple samples with different reagents.
Seamless Endosafe EndoScan-V Integration
Endosafe EndoScan-V Version 6.2 and above perfectly align with 21 CFR Part 11 regulations, providing extensive and searchable audit trails for electronic records. This software enables users to effortlessly implement, integrate, and comply with data integrity guidelines on a global scale. The combination of the PRS 3 system and EndoScan-V software streamlines the process of generating accurate raw data analysis for reporting, tracking, and trending bacterial endotoxin testing.
Effortless Usage & Low Maintenance
With the PRS 3, there's no need to worry about replacing halogen bulbs or dealing with filter changes. Equipped with a long-lasting xenon flash lamp light source, this instrument ensures consistent performance throughout its lifetime. Moreover, the single monochromator filter covers a wide range of UV wavelengths, from 200 nm to 999 nm, enhancing sample processing efficiency and minimizing downtime.
Self-test Reporting for Added Convenience
Each time the instrument is powered on, an on-board diagnostic self-test automatically runs, guaranteeing optimal functionality. Users can generate and print self-test reports within the EndoScan-V software for easy reference. Calibration test plates are also available for purchase, providing clients with the option to perform additional checks. Our dedicated support teams are always ready to assist you with any inquiries.

Endosafe® Trillium™ rCR Technical Report
To further demonstrate the robustness and validity of our Trillium rCR matrix and formulation, we published a technical report detailing the results of our comprehensive beta test study program. The report highlights assay equivalency to our FDA-licensed kinetic LAL assay via our primary alternate method validation.
Download the Report
Microplate Reader Instruments & Support
We are committed to providing clients with a simple upgrade process from the BioTek ELx808 Microplate Reader. A full equivalency study has been completed between ELx808 and PRS 3 for bacterial endotoxin testing using LAL and rCR reagents. Our technical support team qualified the instrument for compatibility with EndoScan-V software for bacterial endotoxin testing using LAL and rCR reagents. This service provides a smooth transition for replacing a BioTek microplate reader instrument for BET testing. Our onsite annual qualification of the instrument and software provides the assurance that it is operating correctly and fulfills the recommended preventative maintenance.
Agilent Technologies has discontinued the BioTek Incubating Microplate Reader Model ELx808. As we continue to partner with Agilent Technologies, they have guaranteed service support of the ELx808 through January 2029.
Comparison of Biotek Elx808 and Endosafe PRS 3
| ELx808 | PRS 3 | |
|---|---|---|
| Light Source | Halogen bulb, requires replacement frequently | Xenon flash lamp, lasts duration of instrument life |
| Wavelength Selection | Filters | Monochromator |
| Wavelength Range | 340-900 nm | 200-999 nm |
| Loading Method | Top-loading | Front-Loading |
| Weight | 35 lbs (15.87 kg) | 25 lbs (11.34 kg) |
| Dimensions | 16.0" D x 15.5" W x 8.75" H (40.6 cm x 39.37 cm x 22.2 cm) | 8.5” H x 12.75” W x 15.5” D (22 x 32.3 x 39.54 cm) |
| Power | 24-volt external power supply compatible with 100-240 V~ ± 10% @ 50-60 Hz | External 24 VDC power supply compatible with 100−240 volts AC at 50−60 Hz. 60 W maximum consumption. |
| Ports | Serial/Parallel | 1 USB Type-A |
Note: Charles River has performed a full equivalency study between the ELx808 and PRS 3 for bacterial endotoxin testing using LAL and rCR reagents.
Microplate Reader Instruments & Support Product Codes
-
PRS 3 Microplate Reader Instrument & Accessories
PRS 3 Microplate Reader Instrument & Accessories Product Code Endosafe® PRS 3 + Endosafe® EndoScan-V™ Software Package
- PRS 3 instrument
- EndoScan-V™ software
- Power supply
- Power adapter
- USB cable
- One-year warranty
M360K Endosafe® PRS 3 (Instrument Only) M300 Universal Test Plate for Plate Reader M400 -
PRS 3 Microplate Reader Instrument Service & Support
PRS 3 Microplate Reader Instrument Service & Support Product Code PRS 3 Reader/Software Maintenance + Qualification On-site PRS500 PRS 3 Remote Qualification Service PRS500RS PRS 3 Reader/Software IQ/OQ/PQ On-site + 0.5 Day Training
(Existing User)PRS501 PRS 3 Reader/Software IQ/OQ/PQ On-site + 1 Day Training
(New User)PRS502 PRS 3 Remote Installation Support for System Upgrade
(Existing User)PRS501RS PRS 3 Remote Installation Support for New System
(New User - Remote Regions Only)PRS502RS PRS 3 Service Contract PRS505 PRS 3 Service Contract – Annual Scheduled Qualification and 2 PM Services + 1 corrective PRS505FS Plate Reader Calibration – Plate Recertification TS950 -
BioTek ELx808 Microplate Reader Instrument & Accessories
BioTek ELx808 Microplate Reader Instrument & Accessories Product Code BioTek Incubating Microplate Reader Package (with 340, 405, 450, 490, 630 nm filters)
- BioTek instrument
- EndoScan-V software
M260K BioTek Incubating Microplate Reader Instrument (with 340, 405, 450, 490, 630 nm filters) M200 Universal Test Plate for Plate Reader M400 Plate Reader Calibration – Plate Recertification TS950 BioTek Bulb M700 -
BioTek ELx808 Microplate Reader Instrument Service & Support
BioTek ELx808 Microplate Reader Instrument Service & Support Product Code Annual Qualification of Instrument/Software* TS500 IQ/OQ/PQ (document only) TS550 On-site Training for Instrument/Software* TS400 *Travel expense applicable
Contact your Client Implementation representative to review service package availability and coverage or request additional details here.
Are you confident that you are using the best BET method to reach your organization's goals?
With companies looking for ways to increase their data integrity compliance and operational efficiencies, simply answer these 5 questions to see which endotoxin test method is best for your organization’s testing requirements.
Take the Quiz
Frequently Asked Questions (FAQs) About Microplate Reader Instruments
-
Which microplate reader instruments does Charles River support?
Currently we support the PRS 3 and BioTek ELx808.
Agilent Technologies has discontinued the BioTek Incubating Microplate Reader Model ELx808, Charles River Product Code M200. As we continue to partner with Agilent Technologies, they have guaranteed service support of the ELx808 through January 2029.
-
Can I use Endosafe EndoScan-V software with my microplate reader instrument?
Yes, you can use Endosafe EndoScan-V software with the PRS 3 and BioTek ELx808.
-
What endotoxin testing reagents can I use on my microplate reader instrument?
The PRS 3 microplate reader instrument is compatible with these Endosafe endotoxin testing reagents: Kinetic Turbidimetric LAL (KTA), Kinetic Turbidimetric LAL (KTA2), Kinetic Chromogenic LAL (KCA), and Recombinant Cascade Reagent rCR (Trillium™).
The BioTek ELx808 microplate reader instrument is compatible with these Endosafe endotoxin testing reagents: Kinetic Turbidimetric LAL (KTA), Kinetic Turbidimetric LAL (KTA2), Kinetic Chromogenic LAL (KCA), and Recombinant Cascade Reagent rCR (Trillium™).